3-18 Encore Multi-port DSU/CSU User GuideÑJuly, 1997
3
source is overridden and the alternate source (if available) or INTERNAL is used.
When neither the main nor the alternate clock sources is available, INT
(INTERNAL) is used.
Table 3-5 AUX
Parameter Setting Description
Framing ESF or D4 DefaultÑESF. Select the DS1 DTE framing format for
the auxiliary port.
Line Code B8ZS or AMI DefaultÑB8ZS. Select the DS1 T1 line code format for
the auxiliary port.
Bit 7 StufÞng Enabled or
Disabled
DefaultÑEnabled. EnabledÑThe timeslots allocated
to the auxiliary DS1 port are in BIT 7 STUFFING
mode. This mode substitutes zero timeslots with 30H
(the second most signiÞcant bit is one).
DisabledÑDisables this function.
Equalization 0Õ to 133Õ, 133Õ to
266Õ, 266Õ to 399Õ,
399Õ to 533Õ and
533Õ to 655Õ
DefaultÑ0Õ to 133Õ. When you connect the ancillary
equipment or the PBX to the AUX port, you may
need to increase the distance between the DSU/CSU
and the DS1 cross connect (patch panel) or the DS1
device. To do this, set the line equalization. With DS1
cross connect, select the distance between the
DSU/CSU and the DS1 cross connect
(maximumÑ655 ft.). With DS1 DTE device, select the
double the distance between the
DSU/CSU and the
DS1 DTE device (maximum Ñ1300 ft.).
Alarm Signal Framed or
Unframed
DefaultÑUnframed. The VX Encore can send either
an unframed or framed alarm signal to the PBX. This
feature provides for: FramedÑ Sends framed all ones
to the Aux port. UnframedÑ Sends unframed all
ones to the Aux port.