Technical SpeciÞcations A-9
A
Front Panel Test Jacks
The three monitor jacks on the front panel enable you to test the T1 line without
disrupting the equipment using T1 test equipment.
The three monitor jacks are SND MON, SND IN, and RCV MON.
PORT 1 and
PORT 2
TD Green
OFF
DTE transmitting pulses; DSU/CSU detecting pulses (1s)
from DTE.
DSU/CSU not detecting pulses from DTE or no DTE
connected to data port.
RD Green
OFF
DTE receiving pulses from DSU/CSU.
DTE receiving no pulses from DSU/CSU.
RTS Yellow
OFF
RTS line from DTE asserted.
RTS line from DTE not asserted.
CTS Yellow
OFF
CTS line to DTE asserted.
CTS line to DTE not asserted
DTR Yellow
OFF
DTR line from DTE is asserted.
DTR line from DTE not asserted.
DATA/TEST Yellow
OFF
DTR line from DTE is asserted.
DTR line from DTE not asserted.
AUX Solid green
OFF
Ancillary
equipment or PBX transmitting or detecting
pulses.
Ancillary
equipment or PBX not transmitting or detecting
pulses.
Table A-11
Front Panel LEDs (Continued)
Item LED Description
Page view 156