4-27
Waveform Window
Searching with Breakpoint Groups
After creating a breakpoint group and defining expressions, you can
use the breakpoint group to perform searches on enabled
expressions. Each VirSim window includes a Breakpoint Group icon
to open a menu of available breakpoint groups. All windows linked to
the same Link group use the same breakpoint group.
1. In any window, click left on the Breakpoint Groups icon to open
the Breakpoint Groups Menu and choose the desired breakpoint
group. If the breakpoint group contains enabled expressions, the
Search arrows in the toolbar are sensitized.
2. Click left on either the forward or backward search arrows to
perform the breakpoint search. The C1 cursor stops at each
breakpoint. In the previous example, select FindXOR and click left
on forward search to locate the next XOR execution.
Collecting and Displaying Unique Events
The Unique Events feature allows you to display symbols for unique
events in the Waveform Window, Register Window, and Logic
Browser. This is a Verilog only feature. By default, display of unique
events is on. To turn off display of unique events, click left on the
Display Menu in the menu bar and click Unique Events. Two types of
unique events are currently available: glitch and user defined.
Glitch events provide an indication that a signal has multiple value
changes within one simulation time. They are always marked by
a yellow diamond. When you place the cursor on the glitch event
marker, the signal name and the message "multiple value
changes" appear in the status bar.