Page view 164
5-7
Source Window
Before Using the Source Window
Verilog
Verilog source information can come from either the Verilog source
or from the simulator PLI for certain simulators. The VCD+ file
produced by VCS or Scirocco when compiled with the -line option
contains information that allows the VirSim Source Window to work
without first compiling the source. When the VCD+ file is from other
simulators, the Verilog source must be compiled by VirSim. The Load
Sources dialog will automatically pop up if VirSim needs to compile
sources and source file information was not provided on the command
line. The source files do not necessarily need to reside in your local
directory; however, if they do not, you must provide the full path. You
may provide the source arguments on the VirSim command line, and
the compilation then will be performed when the information first is
required.
Line trace information can come from either a VCD+ file or via a PLI
from an interactive run. For line trace data to be stored in the VCD+
file, the simulator must have been explicitly instructed to store line
trace information in the Verilog code using $vcdplustraceon. When
the information is coming from a VCD+ file created with a simulator
other than VCS, the VCD+ file also must have been opened with the
Use Sources switch enabled (which is the default).
VHDL
You need to analyze the source code in debug mode before running
simulation.
Page view 164