19-5
Viewing OpenVera Assertions
Viewing OVA Results in VirSim
You can view OVA results in VirSIm from a VCS, Scirocco, or Mixed-
HDL simulation run if a design is compiled with the -ova_debug or
-ova_debug_vpd option.
To view the assertion results, start VirSim and load the VPD file from
the simulation run. Then go to the scope where the assertion is
declared. The scope shows the assertion plus design signals and
OVA variables related to the assertion. Drag the assertion and any
other signals of interest into the Waveform Viewer. Use the features
of VirSim to debug the results in the same way as debugging other
simulation results.
Figure 19-3 shows the Waveform Viewer with four
assertions.
Figure 19-3 VirSim Display of Assertion Results